complexType "eDispatch"
Namespace:
Content:
complex, 6 elements
Defined:
globally in eDispatch_v3.xsd; see XML source
Includes:
definitions of 6 elements
Used:
never
Content Model Diagram
XML Representation Summary
<...>
   
Content: 
eDispatch.01, eDispatch.02, eDispatch.03?, eDispatch.04?, eDispatch.05?, eDispatch.06?
</...>
Content Model Elements (6):
XML Source (w/o annotations (6); see within schema source)
<xs:complexType id="eDispatch.DispatchInformation" name="eDispatch">
<xs:sequence>
<xs:element id="eDispatch.ComplaintReportedbyDispatch" name="eDispatch.01" type="ComplaintReportedByDispatch"/>
<xs:element id="eDispatch.EMDPerformed" name="eDispatch.02" nillable="true">
<xs:complexType>
<xs:simpleContent>
<xs:extension base="EMDPerformed">
<xs:attribute name="NV" use="optional">
<xs:simpleType>
<xs:union memberTypes="NV.NotApplicable NV.NotRecorded"/>
</xs:simpleType>
</xs:attribute>
</xs:extension>
</xs:simpleContent>
</xs:complexType>
</xs:element>
<xs:element id="eDispatch.EMDCardNumber" minOccurs="0" name="eDispatch.03" type="EMDCardNumber"/>
<xs:element id="eDispatch.ComputerAidedDispatchCADNameorID" minOccurs="0" name="eDispatch.04" type="ComputerAidedDispatchCADNameorID"/>
<xs:element id="eDispatch.DispatchPriorityPatientAcuity" minOccurs="0" name="eDispatch.05" type="DispatchPriority"/>
<xs:element id="eDispatch.UnitDispatchedCADRecordID" minOccurs="0" name="eDispatch.06" type="UnitDispatchedCADRecordID"/>
</xs:sequence>
</xs:complexType>
Content Element Detail (all declarations; defined in this component only; 6/6)
eDispatch.01
Type:
eDispatch.01 Complaint Reported by Dispatch Yes Yes The complaint dispatch reported to the responding unit. E03_01 Mandatory Airway Cardiac Arrest Pediatric Response STEMI Stroke Trauma Added Pandemic/Epidemic/Outbreak. <br/>Added Automated Crash Notification <br/>Added Healthcare Professional Admission <br/>Added Transfer/Interfacility/Palliative Care <br/>- Other entries expanded based on current national EMD Dispatch List
Simple Content
enumeration of xs:string
Enumeration:
"2301001"
 - 
Abdominal Pain/Problems
"2301003"
 - 
Allergic Reaction/Stings
"2301005"
 - 
Animal Bite
"2301007"
 - 
Assault
"2301009"
 - 
Automated Crash Notification
"2301011"
 - 
Back Pain (Non-Traumatic)
"2301013"
 - 
Breathing Problem
"2301015"
 - 
Burns/Explosion
"2301017"
 - 
Carbon Monoxide/Hazmat/Inhalation/CBRN
"2301019"
 - 
Cardiac Arrest/Death
"2301021"
 - 
Chest Pain (Non-Traumatic)
"2301023"
 - 
Choking
"2301025"
 - 
Convulsions/Seizure
"2301027"
 - 
Diabetic Problem
"2301029"
 - 
Electrocution/Lightning
"2301031"
 - 
Eye Problem/Injury
"2301033"
 - 
Falls
"2301035"
 - 
Fire
"2301037"
 - 
Headache
"2301039"
 - 
Healthcare Professional/Admission
"2301041"
 - 
Heart Problems/AICD
"2301043"
 - 
Heat/Cold Exposure
"2301045"
 - 
Hemorrhage/Laceration
"2301047"
 - 
Industrial Accident/Inaccessible Incident/Other Entrapments (Non-Vehicle)
"2301049"
 - 
Medical Alarm
"2301051"
 - 
No Other Appropriate Choice
"2301053"
 - 
Overdose/Poisoning/Ingestion
"2301055"
 - 
Pandemic/Epidemic/Outbreak
"2301057"
 - 
Pregnancy/Childbirth/Miscarriage
"2301059"
 - 
Psychiatric Problem/Abnormal Behavior/Suicide Attempt
"2301061"
 - 
Sick Person
"2301063"
 - 
Stab/Gunshot Wound/Penetrating Trauma
"2301065"
 - 
Standby
"2301067"
 - 
Stroke/CVA
"2301069"
 - 
Traffic/Transportation Incident
"2301071"
 - 
Transfer/Interfacility/Palliative Care
"2301073"
 - 
Traumatic Injury
"2301075"
 - 
Well Person Check
"2301077"
 - 
Unconscious/Fainting/Near-Fainting
"2301079"
 - 
Unknown Problem/Person Down
"2301081"
 - 
Drowning/Diving/SCUBA Accident
"2301083"
 - 
Airmedical Transport
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eDispatch.ComplaintReportedbyDispatch" name="eDispatch.01" type="ComplaintReportedByDispatch"/>

eDispatch.02
Type:
anonymous (extension of EMDPerformed), simple content
Nillable:
(can be declared as nil using xsi:nil attribute in instance XML documents)
eDispatch.02 EMD Performed Yes Yes Indication of whether Emergency Medical Dispatch was performed for this EMS event. E03_02 Required Airway Cardiac Arrest Pediatric Response STEMI Stroke Trauma
Simple Content
enumeration of xs:string
Enumeration:
"2302001"
 - 
No
"2302003"
 - 
Yes, With Pre-Arrival Instructions
"2302005"
 - 
Yes, Without Pre-Arrival Instructions
"2302007"
 - 
Yes, Unknown if Pre-Arrival Instructions Given
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eDispatch.EMDPerformed" name="eDispatch.02" nillable="true">
<xs:complexType>
<xs:simpleContent>
<xs:extension base="EMDPerformed">
<xs:attribute name="NV" use="optional">
<xs:simpleType>
<xs:union memberTypes="NV.NotApplicable NV.NotRecorded"/>
</xs:simpleType>
</xs:attribute>
</xs:extension>
</xs:simpleContent>
</xs:complexType>
</xs:element>

eDispatch.03
Type:
EMDCardNumber, simple content
eDispatch.03 EMD Card Number No No The EMD card number reported by dispatch, consisting of the card number, dispatch level, and dispatch mode E03_03 Optional Airway Cardiac Arrest Pediatric Response STEMI Stroke Trauma
Simple Content
xs:string
maxLength:
10
minLength:
1
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eDispatch.EMDCardNumber" minOccurs="0" name="eDispatch.03" type="EMDCardNumber"/>

eDispatch.04
Type:
eDispatch.04 Dispatch Center Name or ID No No The name or ID of the dispatch center providing electronic data to the PCR for the EMS agency, if applicable. Optional This element can be used to identify the dispatch center (Primary or Secondary Public Safety Answering Point - PSAP) that dispatches the EMS agency. If the EMS agency is able to populate the Patient Care Report (PCR) with CAD specific details (times, incident address information, crew information, EMD, etc.) the name or ID of the dispatch center should be documented. Added to the dataset to assist in identifying the CAD / dispatch center providing information to the EMS agency and ePCR when there are multiple dispatch centers sending resources to the same EMS incident.
Simple Content
xs:string
maxLength:
100
minLength:
2
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eDispatch.ComputerAidedDispatchCADNameorID" minOccurs="0" name="eDispatch.04" type="ComputerAidedDispatchCADNameorID"/>

eDispatch.05
Type:
DispatchPriority, simple content
eDispatch.05 Dispatch Priority (Patient Acuity) No No The actual, apparent, or potential acuity of the patient's condition as determined through information obtained during the EMD process. Optional <br/>The use of acuity values vary by EMS agency. Some systems may utilize fewer than four levels and some more. The use of four levels is to capture the majority and allow for the inclusion of the NHTSA National EMS Core Content definitions for patient acuity, specifically: Critical, Emergent, and Lower Acuity. <br/> <br/><span style="color:red">Provided below is an example application only. This example bears no relationship to any particular federal, state, or agency billing requirement. </span> <br/> <br/>For EMS Agencies and CAD / EMD systems utilizing Alpha-Echo, Omega levels for determining the priority level for dispatch of the EMS unit, the recommended mapping is: <br/> <table cellpadding="2px" cellspacing="0px" border="1px"> <tr> <td>Echo = Critical</td><td>Charlie = Emergent</td><td>Alpha = Lower Acuity</td> </tr><tr> <td>Delta = Critical</td><td>Bravo = Emergent</td><td>Omega = Non-Acute</td> </tr></table> <br/>Patient Acuity definitions related to "Critical, Emergent, and Lower Acuity" can be found in the National EMS Core Content document from NHTSA EMS (DOT HS 809-898 July 2005) at http://www.nhtsa.gov/people/injury/ems/emscorecontent/images/EMSCoreContent.pdf <br/> <br/>For Air Medical Transports the most appropriate values choices should be limited to two: Emergent and Non-Acute.
Simple Content
enumeration of xs:string
Enumeration:
"2305001"
 - 
Critical
"2305003"
 - 
Emergent
"2305005"
 - 
Lower Acuity
"2305007"
 - 
Non-Acute [e.g., Scheduled Transfer or Standby]
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eDispatch.DispatchPriorityPatientAcuity" minOccurs="0" name="eDispatch.05" type="DispatchPriority"/>

eDispatch.06
Type:
eDispatch.06 Unit Dispatched CAD Record ID No No The unique ID assigned by the CAD system for the specific unit response. <v2Number/> Optional The Unit Dispatched CAD Record ID is populated from a CAD system. This information will not be known to the EMS professional. <br/><br/> Use Case: Some CAD systems may use the Unit Dispatched CAD Record ID as the Patient Care Report Number (eRecord.01). This may also be a GUID from a CAD system. A GUID for the CAD push to remain unique as updates are sent from CAD. This could be a stream and unique to the record or patient depending on the capabilities of the CAD system. How the Unit Dispatched CAD Record ID is created could vary as it could be a concatenation of multiple elements or a true GUID. <performanceMeasuresGroup/>
Simple Content
xs:string
maxLength:
50
minLength:
3
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eDispatch.UnitDispatchedCADRecordID" minOccurs="0" name="eDispatch.06" type="UnitDispatchedCADRecordID"/>