element -> <eMedDevice.HeartRateGroup>
Group Tag to hold the details of Patient's systolic blood pressure and its procedure
Namespace:
Type:
anonymous complexType
Content:
complex, 2 elements
Defined:
Includes:
definitions of 2 elements
Content Model Diagram
XML Representation Summary
<eMedDevice.HeartRateGroup>
   
Content: 
eMedDevice.27?, eMedDevice.28?
</eMedDevice.HeartRateGroup>
Content model elements (2):
Included in content model of elements (1):
XML Source (w/o annotations (3); see within schema source)
<xs:element id="eMedDevice.HeartRateGroup" minOccurs="0" name="eMedDevice.HeartRateGroup">
<xs:complexType>
<xs:sequence>
<xs:element id="eMedDevice.eVitals.HeartRate" minOccurs="0" name="eMedDevice.27">
<xs:complexType>
<xs:simpleContent>
<xs:extension base="HeartRate"/>
</xs:simpleContent>
</xs:complexType>
</xs:element>
<xs:element id="eMedDevice.eVitals.MethodofHeartRateMeasurement" minOccurs="0" name="eMedDevice.28" type="MethodMeasureHeartRate"/>
</xs:sequence>
</xs:complexType>
</xs:element>
Content Element Detail (all declarations; defined in this component only; 2/2)
eMedDevice.27
Type:
anonymous (extension of HeartRate), simple content
eMedDevice.27 eVitals.10 Heart Rate No No The patient's heart rate expressed as a number per minute. E14_07 Optional Airway Cardiac Arrest Pediatric STEMI Stroke Trauma Pulse Rate and Electronic Monitor Rate have been merged with an additional data element for Method of Heart Rate Measurement.
Simple Content
xs:integer
maxInclusive:
500
minInclusive:
0
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eMedDevice.eVitals.HeartRate" minOccurs="0" name="eMedDevice.27">
<xs:complexType>
<xs:simpleContent>
<xs:extension base="HeartRate"/>
</xs:simpleContent>
</xs:complexType>
</xs:element>

eMedDevice.28
Type:
MethodMeasureHeartRate, simple content
eMedDevice.28 eVitals.11 Method of Heart Rate Measurement No No The method in which the Heart Rate was measured. Values include auscultated, palpated, electronic monitor). Optional This data element was added when Pulse Rate and Electronic Monitor Rate were merged as EVitals.10. This data element was added when Pulse Rate and Electronic Monitor Rate were merged as EVitals.10.
Simple Content
enumeration of xs:string
Enumeration:
"3311001"
 - 
Auscultated
"3311003"
 - 
Doppler
"3311005"
 - 
Electronic Monitor - Cardiac
"3311007"
 - 
Electronic Monitor - Pulse Oximeter
"3311009"
 - 
Electronic Monitor (Other)
"3311011"
 - 
Palpated
XML Source (w/o annotations (1); see within schema source)
<xs:element id="eMedDevice.eVitals.MethodofHeartRateMeasurement" minOccurs="0" name="eMedDevice.28" type="MethodMeasureHeartRate"/>